Turnipseed_TraceGases Instructions Investigator: Andrew Turnipseed, NCAR/ACD turnip@ucar.edu Filenames (comma delimited): Turnipseed_TraceGases.csv Analyzers: Ozone: 2B Technologies Model 205 UV-abs. spectrometer SO2: Thermo Environmental Model 43C-TLE CO2/H2O: Licor Model Li-6262 infrared gas analyzer Measurements are made from 6 inlets at different heights. Measurements are made from each inlet for 5 min., cycling through all 6 inlets over a 30 min. period. These are denoted in the column labeled "Level" Level 1 : z = 1.5 m Level 2: z = 5.0 m Level 3: z = 8.5 m Level 4: z = 12.0 m Level 5: z= 17.7 m Level 6: z = 25.1 m Data Interval: 1 min. average Initial Start time of file: July 5, 2011, 10:18 (MST) Last data point: August 30, 2011, 15:36 (MST) Missing data = NA Data has not been thoroughly checked or flagged for problems. Logged on: Labview VI Columns (for all 4 files): Date/time: MM/DD/YY, HH:mm:ss, End of the 1 min. period (MST) Day of Year: Decimal day, Beginning of 5 min. period (MST) SO2: sulfur dioxide, units = ppbv O3: ozone, units = ppbv CO2: Carbon dioxide, units = ppmv H2O: water vapor, units = mmol/mol Zero: Flag denoting sampling status: 0 = sampling, 1 or 2 = instrument zero Span: Flag denoting sampling status: 0 = sampling, 1 = SO2 span meas., 2 = CO2 span meas. Level: Flag denoting which sampling inlet is active (see above for inlet heights).